Lookup Part! - E1.101
|
Electric Heat Module. 208V 1 phase, 10 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 48 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.201
|
Electric Heat Module. 208V 1 phase, 20 KW maximum - 5 stages, 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 97 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.202
|
Electric Heat Module. 208V 3 phase, 20 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 56 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.204
|
Electric Heat Module. 460V 3 phase, 20 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 26 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.351
|
Electric Heat Module. 208V 1 phase, 35 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 168.27 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.354
|
Electric Heat Module. 460V 3 phase, 35 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 42 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.355
|
Electric Heat Module. 575V 3 phase, 35 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 33.68 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.362
|
Electric Heat Module. 208V 3 phase, 36 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 101 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.401
|
Electric Heat Module. 208V 1 phase, 40 KW maximum - 5 stages, 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 193 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.504
|
Electric Heat Module. 460V 3 phase, 50 KW maximum - 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 62 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.724
|
Electric Heat Module. 460V 3 phase, 72 KW maximum - 5 stages, 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 91 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.765
|
Electric Heat Module. 600V 3 phase, 76 KW maximum - 2 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 15.50" wide and 17.75" tall. 80 Amp service required. 400 to 3,600 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E1.SHELL
|
Electric Heat Module Shell. No controls included. Electric Heater Coil should be 15.50" wide and 17.75" tall. 400 to 3,600 cfm's. Sheet metal enclosure only.
|
|
|
Lookup Part! - E2.1004
|
Electric Heat Module. 460V 3 phase, 100 KW maximum - 6 stages, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 126 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E2.1195
|
Electric Heat Module. 575V 3 phase, 119 KW maximum - 5 stages, 1 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 120 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E2.452
|
Electric Heat Module. 208V 3 phase, 45 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 125 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E2.734
|
Electric Heat Module. 460V 3 phase, 73 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 87.6 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E2.735
|
Electric Heat Module. 575V 3 phase, 73 KW maximum - 2 modulating stages, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 22.63" wide and 23.63" tall. 70.26 Amp service required. 2,000 to 6,500 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E2.SHELL
|
Electric Heat Module Shell. No controls included. Electric Heater Coil should be 22.63" wide and 23.63" tall. 2,000 to 6,500 cfm's. Sheet metal enclosure only.
|
|
|
Lookup Part! - E3.1224
|
Electric Heat Module. 460V 3 phase, 122 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 146.4 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.1225
|
Electric Heat Module. 575V 3 phase, 122 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 117.42 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.1434
|
Electric Heat Module. 460V 3 phase, 133 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 180 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.1755
|
Electric Heat Module. 575V 3 phase, 175 KW maximum - 6 stages, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 176 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.522
|
Electric Heat Module. 208V 3 phase, 52 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 144 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.642
|
Electric Heat Module. 208V 3 phase, 64 KW maximum - 6 stages total, 2 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Coil is 29.50" wide and 29.63" tall. 178 Amp service required. 4,000 to 8,000 cfm's. Sheet metal enclosure included.
|
|
|
Lookup Part! - E3.SHELL
|
Electric Heat Module Shell. No controls included. Electric Heater Coil should be 29.50" wide and 29.63" tall. 4,000 to 8,000 cfm's. Sheet metal enclosure only.
|
|
|
|